power ultrasonic transducers for ultrasonic cleaning equipmen

power ultrasonic transducers for ultrasonic cleaning equipment
Installation technology of ultrasonic transducer:
1. Preparatory tools: Argon arc welding, No. 10 inner hexagonal wrench, chrome-iron-tin wire, 2.5 square high temperature wire, 2*2.5 cable line, oscillator glue, (stripping pliers, casing, tie-up, sand blasting machine, pipe fittings, etc.).
2. Welding screw: Calculate the arrangement position of oscillator, weld the screw in the cleared position, and then clean the screw around, make sure it is flat, so as not to affect the installation of oscillator.
3. Glue disposition: A glue is squeezed around the screw, B glue is squeezed next to A glue, and then AB glue is quickly stirred with a small iron bar to make it fully mixed and even.
4. Install the vibration head: Turn the transducer slightly to squeeze out the air and excess glue between the bottom and the contact surface of the cylinder bottom, so that the oscillator is more closely integrated with stainless steel.
Fifth, solidification and condensation: solidification at relatively high room temperature, 4-8 hours wiring, 24 hours after power test machine.
 
Note: 1. Metal seed nailing machine can also replace argon arc welding.
2. Welding screw must be fully welded, otherwise it is easy to fall off.
3. Regarding curing, the length of time should consider temperature, low temperature for a long time, high temperature for a faster time. It is recommended to operate at room temperature, even if heated, do not overheat, appropriate and best.
Type Length(mm) Weight(g) Frequency(KHz) Resonance Impedance
(Ω)
Static Capacity
(pF)±10%
Input Power(W)
ARS-QXHNQ-20100
PZT-8
94 900 20 10-20 5200 100
ARS-QXHNQ-25100
PZT-4
77 710 25 10-20 6600 100
ARS-QXHNQ-28100
PZT-8
66 625 28 10-20 5200 100
ARS-QXHNQ-28100
PZT-4
66 624 28 10-20 6600 100
ARS-QXHNQ-30100
PZT-8
61 555 30 10-20 5200 100
ARS-QXHNQ-2560
PZT-4
77 530 25 10-20 5400 60
ARS-QXHNQ-2860
PZT-8
68 470 28 10-20 3800 60
ARS-QXHNQ-2850
PZT-4
82 425 28 10-20 4100 50
ARS-QXHNQ-3360
PZT-8
58 420 33 10-20 3800 60
ARS-QXHNQ-4060
PZT-8
55 300 40 10-20 3800 60
ARS-QXHNQ-4060
PZT-4
56 310 40 10-20 5400 60
ARS-QXHNQ-4050
PZT-4
54 260 40 10-20 4100 50
ARS-QXHNQ-4050-1
PZT-4
57 300 40 10-20 4100 50
ARS-QXHNQ-5435
PZT-4
36 135 54 10-20 3200 35
ARS-QXHNQ-6860
PZT-8
80 460 68 10-20 3800 60
ARS-QXHNQ-68120
PZT-4
67 588 68 10-20 7800 120
ARS-QXHNQ-8060
PZT-4
60 325 80 10-20 5400 60
ARS-QXHNQ-12060
PZT-4
56 260 120 10-20 5400 60
ARS-QXHNQ-13550
PZT-4
54 215 135 10-20 4200 50